MINI-Con MINK-CCP 19 Pin #22 Female
Keywords: MINI-Con MINK CCP, MINK-CCP, 19 pin underwater connector, MINK series subsea connector, 600 bar miniature underwater connector, compact subsea connector
- IP68 waterproof
- Up to 7000m
- In-line, 1Pin, Male
- RV POWER GROUP
- [email protected]
-
- Description
- Video
- Downloads
The MINK-CCP is a MINI-Con MINK Series CCP Cable Plug, 19-Pin #22, designed for compact underwater instrument packages requiring high pin density in a small-diameter body. Rated to 600 Bar (8,700 psi) mated with 19 contacts at 300 V / 3 A per contact, the MINK-CCP provides a reliable wet-mate interface for sensors, cameras, and multi-conductor data links where standard 55-series or Micro Circular connectors are too large.
At a glance: 19 pins #22 | 300 V | 3 A/contact | Mated 600 Bar | Open-face 400 Bar | Wet matings >500
Key Design Features
- MINI-Con MINK Series: High-density 19-pin connector in a compact body — bridges the gap between Micro Circular (up to 16 pin) and standard 55-series.
- 19 Contacts, #22 Gauge: Supports up to 57 A total (3 A × 19 contacts) for multi-channel power and signal distribution in a single connector.
- 600 Bar Mated / 400 Bar Open-Face: Suitable for instrument deployments to approximately 6,000 m mated / 4,000 m open-face.
- CCP Wet-Mate Design: Cable-to-cable plug enables field mating underwater with a compatible MINK BCR bulkhead counterpart.
- Chloroprene Rubber Body: Flexible, chemically resistant body suited for repeated dynamic deployment cycles.
- Gold-Plated Contacts: Contact resistance <0.01 Ω; insulation resistance >200 MΩ.
- 316 SS or Titanium Coupling Ring: Corrosion-resistant hardware with POM or SS locking sleeve for secure retention underwater.
- >500 Wet-Mate Cycles: Designed for ROV inspection sensor packs requiring frequent swap-out.
- PUR Cable Jacket: Factory-terminated with polyurethane (PUR) cable for dynamic bend radius service.
Electrical & Mechanical Specifications
| Parameter | Value |
|---|---|
| Model number | MINK-CCP |
| Connector series | MINI-Con MINK Series |
| Configuration | CCP |
| Shell size | — |
| Number of contacts / channels | 19 |
| Voltage rating | 300 V DC/AC rms |
| Current per contact | 3 A per contact |
| Maximum total current | 57 A (19 pin total) |
| Insulation resistance | >200 MΩ |
| Contact resistance | <0.01 Ω |
| Mated pressure rating | 600 Bar (8,700 psi) |
| Open-face pressure rating | 400 Bar (5,800 psi) |
| Wet / dry matings | >500 cycles |
| Temperature rating (water) | −4°C to +60°C |
| Temperature rating (air) | −40°C to +60°C |
| Connector body material | Chloroprene rubber |
| Shell / housing material | 316 Stainless Steel (Titanium on request) |
| Contacts | Gold-plated brass (female) / Gold-plated beryllium copper (male) |
| Locking mechanism | POM or Stainless Steel locking sleeve (mandatory before deployment) |
| O-ring seals | Nitrile |
| Cable jacket | Polyurethane (PUR) or Synthetic Rubber — customer-specified OD |
Typical Applications
- Compact oceanographic instruments requiring high pin count in a small form factor
- Underwater sensor packages — pressure, temperature, conductivity, fluorescence multi-channel
- Small-diameter ROV and AUV instrument payloads
- Subsea camera and lighting systems — power and control in one connector
- Diver instrumentation and mixed-gas dive system sensors
- Acoustic modem and hydrophone array connections
- Compact inspection ROV umbilical breakouts
- Scientific lander and benthic observatory instruments
- Naval sonar transducer element connections
Why Choose the MINK-CCP?
Proven Industry Compatibility
The MINK-CCP is dimensionally compatible with the original series it references, providing direct field replacement without system redesign, re-wiring, or adapter hardware.
Factory Quality Control
Every connector is continuity-tested, insulation-tested, and visually inspected before shipment. Batch pressure test certificates are available on request for programme quality assurance.
Flexible Configuration Options
Available with customer-specified cable type, cable length, body material (SS / Ti / anodised Al), and contact plating to meet specific programme technical requirements.
Competitive Pricing with Short Lead Times
RV Power Group's manufacturing capability and strategic material inventory enable competitive pricing and short lead times versus OEM sources — particularly advantageous for spare parts, emergency replacements, and high-volume projects.
Technical Support
Our subsea connector engineers are available to advise on selection, mating compatibility, and installation — contact [email protected] for application support.
Complete 55-Series & Industry-Standard Connector Range
How to Select Your 55-Series or Compatible Connector
| Selection Criterion | Guidance |
|---|---|
| Shell size | Shell 15 (small, up to 8 pin); Shell 20 (medium, up to 21 pin); Shell 24 (large, 12+ pin); Size M (SEACON MIN-M, 26 pin) |
| Pin count | Match to cable conductor count; select next size up if adding spares |
| Connector type | CCP for cable-to-cable or cable-to-equipment; BCR/FCR for panel/bulkhead mount; PBOF for extreme pressure; RA for right-angle installations; Dummy for connector protection |
| Voltage and current | Shell 15 (2-4 pin): 10 A/contact; Shell 15 (5+ pin): 10 A/contact; Shell 20: 10 A/contact; Shell 24: 5 A/contact |
| EO connectors | Select IE-series (2 or 4 channel) for optical data links; specify SM for runs >100 m, MM for shorter runs |
| PBOF requirement | Use 55P1-1508 PBOF variant when open-face or connector boot cannot be rated for ambient sea pressure (very deep or unusual umbilical designs) |
| Dummy plugs | Always install a dummy plug on unmated bulkhead or cable connectors before deployment to protect contacts and sealing faces |
| Custom requirements | Contact [email protected] for non-standard pin counts, body materials, or pressure test certifications |
Frequently Asked Questions
Q: Is the MINK-CCP compatible with original Burton 55-series connectors?
A: Yes — it is dimensionally compatible with the referenced OEM standard for direct field replacement.
Q: What is the maximum operating depth?
A: Mated pressure is 600 Bar (8,700 psi) (approximately 60 m depth). Open-face rating is 400 Bar (5,800 psi).
Q: How many times can the connector be mated?
A: The MINK-CCP is rated for >500 wet-mate cycles. Inspect and clean contacts every 50 cycles or annually.
Q: What voltage and current does the connector support?
A: 300 V DC/AC rms, 3 A per contact (57 A (19 pin total) total connector limit). Both power and signal circuits can share the same multi-pin connector.
Q: Is a locking sleeve required?
A: Yes — always install the POM or SS locking sleeve after mating and before deployment. Never deploy without the locking sleeve engaged; it prevents accidental unmating under cable tension or sea-state vibration.
Q: Can I mix connector brands (e.g. RV Power Group plug with another brand bulkhead)?
A: Yes — within the referenced standard, connectors from compatible manufacturers mate correctly. Verify thread and contact gender before installation.
Q: What materials are available for the shell and coupling nut?
A: 316 Stainless Steel is the standard. Titanium is available on request for weight-sensitive or corrosion-critical applications. Anodised aluminium is available for above-water or shallow-water applications.
Q: Are pressure test certificates available?
A: Yes — batch or per-unit hydrostatic pressure test certificates can be provided for programme QA requirements. Contact [email protected] to include in your order.
Q: What cleaning and maintenance is required?
A: Before mating: rinse with clean water, inspect contacts for corrosion or debris, apply a thin layer of silicone grease to O-rings. After deployment: rinse with fresh water, cap unused connectors, and store in a clean dry environment. Replace O-rings if cracked or compressed permanently.
Q: Can I order custom cable assemblies with these connectors?
A: Yes. RV Power Group supplies factory-terminated cable assemblies with specified cable type, length, shielding, and lead configuration. Contact [email protected] with your requirements.
Installation, Mating & Maintenance Guidelines
Pre-Deployment Inspection
(1) Visually inspect all contacts for corrosion, deformation, or debris. (2) Check O-rings for cuts, abrasion, or permanent set — replace if in doubt. (3) Apply fresh silicone grease to O-ring surfaces. (4) Confirm locking sleeve moves freely and engages positively. (5) Remove protective caps from both connector halves immediately before mating — minimise air exposure time on flooded dummy plug sockets. (6) If using a PBOF variant, verify oil fill port is sealed and oil level is correct before deployment.
Mating Procedure
(1) Align guide pins/key and insert plug into bulkhead/receptacle with a smooth single-stroke motion. (2) Thread coupling nut by hand until finger-tight. (3) Slide locking sleeve forward until it clicks and locks over the coupling nut. (4) Verify lock by attempting to rotate coupling nut rearward — it should not move when sleeve is engaged. (5) On hybrid EO connectors, verify electrical continuity on power contacts before descent. (6) Log the mating cycle count if operating close to the rated 500-cycle limit.
Storage & Long-Term Maintenance
Store all connectors with protective caps installed in a clean, dry, UV-shaded environment. Flush with fresh water after every seawater exposure. Lubricate O-rings before storage if unit will not be deployed within 30 days. Inspect gold-plated contacts annually — light tarnish is acceptable, pitting or green corrosion requires contact replacement. Return to RV Power Group for factory refurbishment if contact resistance exceeds 0.05 Ω on any circuit. Always document the mating history for programme traceability.
For pricing, availability, custom configurations, and technical support for the MINK-CCP and all MINI-Con MINK Series products, contact [email protected]. Our subsea engineering team responds within one business day.