2 Core Fibre Optic Connector and 2 power underwater BCR connector
Keywords: subsea hybrid opto-electric connector, 2-core fibre optic underwater connector, BCR bulkhead connector, 6,000m depth rated fibre optic connector, 600 bar subsea connector, wet-mate optical connector, hybrid power data, power contacts, ROV fibre optic conn
- IP68 waterproof
- Up to 7000m
- In-line, 1Pin, Male
- RV POWER GROUP
- [email protected]
-
- Description
- Video
- Downloads
The HYBBCR-2F2P is a subsea-rated Hybrid Opto-Electric BCR Bulkhead Connector designed for depths to 6,000 m (600 Bar / 8700 psi). Featuring 2-Core Fibre Optic optical channel(s) with single-mode (SM) or multimode (MM) compatibility and a chloroprene rubber over-moulded body, this connector delivers ultra-low insertion loss, <0.5 dB typical, for critical subsea sensing, imaging, and data-link applications. Combined with 2 power contacts rated at 600 V / 10 A per contact, this hybrid connector delivers simultaneous high-bandwidth optical data and electrical power in a single robust body — eliminating the need for separate cable penetrations. The connector is available as BCR (Bulkhead Connector for dry-box integration), with gold-plated electrical contacts (where fitted), titanium or stainless steel hardware, and POM or SS locking sleeves to ensure secure retention in dynamic sea states.
Key numbers at a glance: Rated depth 6,000 m | Pressure 600 Bar mated | Optical loss <0.5 dB | Return loss >40 dB | Wet matings >500 | Fibre channels 2 | Power contacts 2 × 600 V / 10 A
Key Design Features
- BCR Bulkhead Integration: Dry-box bulkhead connector with jam-nut panel mounting; mates with CCP cable plug on the wet side for reliable feedthrough into instrument pressure housings.
- Ultra-Deep Rating: Qualified to 6,000 m / 600 Bar mated pressure — suitable for full ocean-depth scientific and defence deployments.
- SM & MM Fibre Compatibility: Accepts single-mode (9/125 µm) or multimode (50/125 µm, 62.5/125 µm) fibres; factory-terminated with precision ferrules for <0.5 dB insertion loss.
- Low Insertion Loss: <0.5 dB typical per channel; return loss >40 dB — maintains signal integrity over multi-kilometre fibre runs.
- >500 Wet-Mate Cycles: Chloroprene rubber wipers and precision alignment bushings sustain repeated in-situ mating without optical performance degradation.
- Hybrid Power + Data: Integrates 2 electrical power contacts (600 V / 10 A per contact, max 20 A) alongside optical fibres — one connector replaces two separate penetrations.
- Corrosion-Resistant Materials: Chloroprene rubber over-mould with titanium, 316 SS, or anodised aluminium options; gold-plated electrical contacts resist seawater corrosion for the design service life.
- Locking Sleeve Security: POM or stainless steel locking sleeves (MANDATORY before deployment) prevent accidental de-mating under ROV cable tension or sea-state vibration.
- Polyurethane (PUR) Cable Over-Mould: Factory-terminated PUR cable jacket provides flexible, kink-resistant strain relief rated for continuous dynamic service.
- Custom Configuration: Available with customer-specified cable lengths, fibre types, contact plating, and body material; pressure testing certificates available per unit.
Electrical & Mechanical Specifications
| Parameter | Value |
|---|---|
| Connector model | HYBBCR-2F2P |
| Connector type | BCR (Bulkhead Connector for dry-box integration) |
| Fibre optic channels | 2 |
| Compatible fibre types | SM 9/125 µm; MM 50/125 µm; MM 62.5/125 µm |
| Typical insertion loss | <0.5 dB per channel |
| Return loss | >40 dB |
| Rated depth | 6,000 m |
| Mated pressure rating | 600 Bar (8700 psi) |
| Open-face pressure rating | Not rated for open-face exposure (fibre optic) |
| Wet/splash matings | >500 cycles |
| Power contacts | 2 electrical contacts |
| Electrical voltage rating | 600 V DC/AC rms |
| Electrical current per contact | 10 A per contact (max 20 A total) |
| Electrical insulation resistance | >200 MΩ |
| Electrical contact resistance | <0.01 Ω |
| Temperature rating (water) | −4°C to +60°C |
| Temperature rating (air) | −40°C to +60°C |
| Connector body material | Chloroprene rubber over-mould |
| Bulkhead / hardware material | Titanium / 316 Stainless Steel / Anodised Aluminium (customer-specified) |
| Locking sleeves | POM or Stainless Steel (mandatory before deployment) |
| Cable jacket (inline) | Polyurethane (PUR), customer-specified OD |
| Fibre termination | Factory-polished precision ferrule |
| O-ring seals | Nitrile |
Typical Applications
- ROV and AUV fibre tether systems — high-bandwidth video, sonar, and sensor data return
- Subsea observatory nodes and cabled ocean observatories (NEPTUNE, EMSO, ONC)
- Deep-sea instrument packages requiring high-speed optical data links at >6,000 m
- Acoustic Doppler Current Profiler (ADCP) and multibeam echo-sounder integration
- Subsea cameras and USBL positioning systems with digital video uplink
- Combined power and data tether for untethered AUV charging and communications
- Naval and defence underwater sensor networks and sonar arrays
- Oceanographic winch systems and towed array connectors
- Oil and gas subsea tree monitoring — fibre-optic distributed temperature sensing (DTS)
- Offshore wind scour monitoring sensors with seabed data nodes
Why Choose the HYBBCR-2F2P Hybrid Connector?
Certified Ultra-Deep Performance
The HYBBCR-2F2P is pressure-rated to 600 Bar (6,000 m depth), exceeding the requirements of most working-class ROV and scientific AUV systems. Every connector is hydro-tested before shipment, with pressure certificates available on request for programme QA compliance.
Factory-Terminated for Guaranteed Optical Performance
Fibre termination is performed in a controlled factory environment using precision ceramic or zirconia ferrules and automated polishing equipment, delivering insertion loss <0.5 dB and return loss >40 dB — performance levels that field termination cannot reliably achieve in offshore environments.
Wet-Mate Durability Over 500 Cycles
Chloroprene rubber wipers sweep the optical face clean during mating, while precision guide pins ensure repeatable fibre alignment. The connector is rated for >500 wet-mate cycles without measurable insertion loss increase — critical for ROV tooling systems requiring frequent connect/disconnect under water.
Hybrid Single-Cable Solution
By integrating optical fibres and power contacts in a single connector body, the HYBBCR-2F2P eliminates the need for parallel cable runs and multiple penetrations — reducing drag on tethers, simplifying ROV panel layout, and improving overall system reliability.
Tailored to Your System Requirements
RV Power Group manufactures the HYBBCR-2F2P to order with customer-specified fibre type (SM/MM/PM), cable OD, body material (titanium, SS, anodised Al), contact count (for hybrid variants), and cable length. IEC 60793 and IEC 61300 test reports are available for quality-critical programmes.
Hybrid Opto-Electric Connector Family
| Product Title | Model | Type | Fibre Channels | Depth / Pressure | Power Contacts? |
|---|---|---|---|---|---|
| Single-Fibre Connector CCP 6,000 metre standard depth rating | FOCCCP-1F-6K | CCP | 1 ch | 6,000 m / 600 Bar | No |
| Single Fibre BCR for dry box 6,000 metre standard depth rating | FOCBCR-1F-6K | BCR | 1 ch | 6,000 m / 600 Bar | No |
| 4 Core Fibre Optic Connector CCP 8,000 metre standard depth rating | FOCCCP-4F-8K | CCP | 4 ch | 8,000 m / 800 Bar | No |
| 4 Core Fibre Optic Connector BCR 8,000 metre standard depth rating | FOCBCR-4F-8K | BCR | 4 ch | 8,000 m / 800 Bar | No |
| 2 Core Fibre Optic Connector and 2 power underwater CCP connector | HYBCCP-2F2P | CCP | 2 ch | 6,000 m / 600 Bar | Yes |
| 2 Core Fibre Optic Connector and 2 power underwater BCR connector | HYBBCR-2F2P | BCR | 2 ch | 6,000 m / 600 Bar | Yes |
| 4 Core Fibre Optic Connector and 2 power underwater connector | HYBCCP-4F2P | CCP | 4 ch | 6,000 m / 600 Bar | Yes |
| 12 Core Fibre Optic Connector and 2 power underwater connector | HYBCCP-12F2P | CCP | 12 ch | 6,000 m / 600 Bar | Yes |
How to Select Your Subsea Fibre Optic Connector
| Selection Criterion | Guidance |
|---|---|
| Connector type | Choose CCP for cable-to-cable in-line mating (ROV tether, sensor pigtails); choose BCR for panel/bulkhead feedthrough into pressure housings or dry boxes |
| Fibre count | 1 fibre for simple camera/telemetry links; 4 fibres for multi-channel sensors; 12 fibres for switch-based subsea LAN nodes |
| Fibre type | Single-mode (SM) for runs >100 m or 10 Gbit/s links; multimode (MM) for <100 m, 1 Gbit/s or instrument-based OTDR systems |
| Depth rating | 6,000 m (600 Bar) for standard scientific ROVs; 8,000 m (800 Bar) for full-ocean-depth landers and hadal vehicles |
| Hybrid power | Select hybrid (2 power contacts) when you need simultaneous power and data — eliminates a second cable penetration through the tether or housing |
| Locking sleeve | Always install POM or SS locking sleeve before deployment; retain for re-mating cycles |
| Custom requirements | Contact [email protected] for non-standard fibre types (PM, bend-insensitive), non-standard body materials, or batch pressure testing |
Frequently Asked Questions
Q: What is the difference between a CCP and BCR connector?
A: CCP (Cable-to-Cable Plug) is the wet-mate cable-terminated plug that connects underwater. BCR (Bulkhead Connector) is a panel-mounted feedthrough for dry-box or instrument-housing integration — the CCP cable plug mates into the BCR bulkhead from the wet side.
Q: What fibre types are supported?
A: Standard options are single-mode 9/125 µm (OS1/OS2) and multimode 50/125 µm or 62.5/125 µm (OM2–OM4). Polarisation-maintaining (PM) and bend-insensitive fibres are available on request.
Q: What data rate can the optical link support?
A: Connector insertion loss (<0.5 dB) is compatible with 10 Gbit/s single-mode links and 1 Gbit/s multimode links over typical subsea tether lengths. Actual data rate depends on total system loss budget and transceiver characteristics.
Q: How many times can the connector be mated underwater?
A: The HYBBCR-2F2P is rated for >500 wet-mate cycles. Chloroprene wipers protect the optical face during mating; inspect and clean faces per the maintenance schedule every 50 cycles or annually.
Q: What is the rated depth and mated pressure?
A: The HYBBCR-2F2P is rated to 6,000 m depth / 600 Bar mated pressure (8700 psi). Hydrostatic pressure certificates are available per unit on request.
Q: Is the connector rated for open-face (unmated) pressure exposure?
A: No — unlike electrical SubConn® connectors, the optical face must be protected by a dust/moisture cap when unmated. Do not expose the bare optical ferrule to seawater pressure without the mating counterpart or protective cap installed.
Q: What cleaning procedure is required before mating?
A: Inspect both optical faces with a fibre scope before each mating cycle. Clean with a dry, lint-free ferrule cleaner (e.g., Cletop stick) — do not use alcohol wipes offshore unless fully dried. Install locking sleeve after mating.
Q: Can I specify the cable length and type?
A: Yes. The HYBBCR-2F2P is factory-terminated to order with customer-specified PUR cable length, OD, and fibre type. Minimum order quantity and lead times apply — contact [email protected] for a quotation.
Q: Are pressure test certificates available?
A: Yes. Certified hydrostatic pressure testing to the rated depth is available on a per-unit basis and is recommended for programme-critical applications. Certificates reference the tested pressure, date, and connector serial number.
Q: Can the hybrid connector carry both power and optical signals simultaneously?
A: Yes. The HYBBCR-2F2P routes optical fibre channels and 2 electrical power contacts (600 V / 10 A each) through a single body with full optical-electrical isolation. There is no crosstalk between the optical and electrical sections.
Q: What is the maximum electrical current for the hybrid version?
A: Each power contact is rated 10 A, giving a maximum of 20 A total per connector. For higher current requirements, contact us for custom multi-contact power designs.
Installation, Mating & Maintenance Guidelines
Pre-Deployment Inspection
Before every deployment: (1) Inspect optical faces with a fibre microscope — reject any connector with scratches crossing the core region. (2) Clean ferrule faces with a dry Cletop or equivalent tool. (3) Inspect chloroprene wiper rings for cuts or deformation. (4) Verify O-rings are lightly greased with silicone grease. (5) Confirm locking sleeve is fully engaged after mating — listen/feel for the positive click. Never deploy without the locking sleeve.
Mating Procedure
(1) Remove protective caps from both CCP and BCR (or both CCP faces) immediately before mating — minimise air exposure time. (2) Align guide pins and insert CCP into BCR with a smooth single-stroke push — do not rotate the optical body during insertion. (3) Slide locking sleeve forward until locked. (4) Perform a quick-check optical power measurement if an OTDR or light source is accessible. (5) Verify electrical continuity on hybrid connectors before deployment.
Storage & Long-Term Maintenance
Store unmated connectors with protective caps installed; keep in a clean, dry environment. Inspect and clean optical faces every 50 cycles or at least annually. Replace chloroprene wiper O-rings every 2–3 years or if visible cracking appears. Do not use abrasive cleaners on the chloroprene body. Return to RV Power Group for factory refurbishment if insertion loss exceeds 1.0 dB on any channel.